ABC/HR for Java, Version 0.52b, 12 August 2007 Testname: Sample15 - Gypsy Tester: thana 1R = Sample15\Sample15_3.wav 2L = Sample15\Sample15_2.wav 3L = Sample15\Sample15_1.wav 4L = Sample15\Sample15_5.wav 5L = Sample15\Sample15_4.wav Ratings on a scale from 1.0 to 5.0 --------------------------------------- General Comments: --------------------------------------- 1R File: Sample15\Sample15_3.wav 1R Rating: 2.0 1R Comment: smearing of instruments, serious loss of stereo field --------------------------------------- 3L File: Sample15\Sample15_1.wav 3L Rating: 2.5 3L Comment: annoying smearing of instruments --------------------------------------- 4L File: Sample15\Sample15_5.wav 4L Rating: 4.0 4L Comment: very slight smearing of instruments --------------------------------------- 5L File: Sample15\Sample15_4.wav 5L Rating: 1.0 5L Comment: lowpassed smeared mess again --------------------------------------- ABX Results: Original vs Sample15\Sample15_5.wav 9 out of 9, pval = 0.0010 ---- Detailed ABX results ---- Original vs Sample15\Sample15_5.wav Playback Range: 03.645 to 06.039 9:37:57 PM p 1/1 pval = 0.5 9:38:00 PM p 2/2 pval = 0.25 9:38:03 PM p 3/3 pval = 0.125 9:38:06 PM p 4/4 pval = 0.062 9:38:09 PM p 5/5 pval = 0.031 9:38:12 PM p 6/6 pval = 0.015 9:38:17 PM p 7/7 pval = 0.0070 9:38:23 PM p 8/8 pval = 0.0030 9:38:26 PM p 9/9 pval = 0.0010